MSC.581(110) Explained: New IMO Recommendations for Enclosed Spaces – and Why CO₂ Now Matters

With Resolution MSC.581(110), the IMO has thoroughly revised its recommendations for entering enclosed spaces aboard ships. The biggest change in practice: before entry, the atmosphere is no longer checked for oxygen alone, but for carbon dioxide (CO₂) as well. Many ships are not yet equipped for this, because a standard 4-gas detector does not measure CO₂.

Woell Marine

Title slide “MSC.581 – CO₂ check on board” by Woell Marine

Key facts at a glance

  • MSC.581(110) (“Revised Recommendations for Entering Enclosed Spaces Aboard Ships”) was adopted by the IMO Maritime Safety Committee (MSC 110) on 27 June 2025 and replaces A.1050(27).
  • It applies to all types of ships and also explicitly addresses port and terminal operators and shore personnel working on board.
  • Entry only after steady readings of 20.9% O₂ and less than 0.5% CO₂ (5,000 ppm), less than 1% LFL and less than 50% of the occupational exposure limit for toxic gases.
  • Everyone entering should carry a calibrated personal gas detector that monitors O₂, CO₂, flammable gases and toxic gases, including CO.
  • Also new: a ship-specific Enclosed Space Register, an enclosed space emergency response plan, and no single-person entry.

Video: MSC.581 in three minutes

Clicking play loads the video from YouTube.

Video (3 min): what counts as an enclosed space, the new entry limits, why CO₂ must be measured, what inspectors check on board and which detectors fit.

What is MSC.581(110)?

MSC.581(110) is a resolution of the IMO’s Maritime Safety Committee (MSC). It revises the recommendations for safe enclosed space entry and replaces the previous Resolution A.1050(27), which the IMO Assembly revoked in December 2025.

Formally, these are recommendations. However, they are closely tied to mandatory rules: SOLAS XI-1/7 requires portable atmosphere testing instruments for enclosed spaces, SOLAS III/19.3.6 requires regular enclosed space entry and rescue drills, and the ISM Code requires the procedures to be part of the safety management system.

What counts as an enclosed space?

Under paragraph 2.1, an enclosed space is a space that may contain a hazardous atmosphere or lack oxygen and has any of the following characteristics:

  • limited openings for entry and exit,
  • inadequate ventilation,
  • not designed for continuous human occupancy.

Examples include cargo holds, bilge spaces, ballast and other tanks, pump-rooms, chain lockers and engine crankcases. The resolution also defines connected and adjacent spaces for the first time, because hazardous gases can migrate, for example via stairways into hold access trunks.

Which limits apply before entry?

ParameterLimit under MSC.581(110), para. 7.4
Oxygen (O₂)20.9% by volume
Carbon dioxide (CO₂) – newless than 0.5% by volume (5,000 ppm)
Flammable gases and vapoursless than 1% of the lower flammable limit (LFL/LEL)*
Toxic gases and vapoursless than 50% of the occupational exposure limit (OEL)

* where the risk assessment has identified a potential for flammable gases or vapours. National requirements may differ.

Testing takes place after the risk assessment, with ventilation stopped and only once readings have stabilised (para. 7.6). The atmosphere should be tested at different levels and areas of the space to account for gas stratification (para. 7.2), and retested regularly while work is in progress.

Why CO₂ is now in focus

Organic cargoes such as grain, timber and wood pellets absorb oxygen and release CO₂ through microbiological degradation (para. 10.5). Other bulk cargoes such as coal can also deplete oxygen and generate CO₂ or CO. What makes this so dangerous:

  • According to Appendix 5, the 0.5% CO₂ workplace exposure limit is already reached at 20.26% oxygen. An oxygen-only detector with the usual 19.5% alarm threshold stays silent.
  • From 4% CO₂, exposure may lead to permanent brain damage, coma or death, while oxygen may still be in the region of 17 to 14% (paras. 10.5.3–10.5.4).
  • Death from CO₂ can precede death from oxygen deficiency (para. 10.5.6). A CO₂-laden atmosphere “looks normal” and gives no sensory warning.

If you only measure oxygen, you detect this hazard too late. Standard 4-gas detectors measure O₂, LEL, CO and H₂S, but not CO₂.

What else MSC.581 requires on board

  • Enclosed Space Register: a ship-specific list of all enclosed spaces, including their connected and adjacent spaces, hazards and risk mitigations (paras. 2.8 and 4.2).
  • No single-person entry into enclosed spaces (para. 3.11).
  • Enough detectors: at least two sets as required by SOLAS XI-1/7. Ships carrying cargo that can generate hazardous vapours and requiring regular entry into cargo spaces should carry two additional sets (para. 7.3). Flexible hoses or fixed sampling lines allow testing without entering the space.
  • CO₂ measurement even when oxygen is low: detectors should operate correctly in an oxygen-depleted atmosphere (para. 7.1).
  • Emergency plan and drills: an Enclosed Space Emergency Response Plan and regular rescue drills (paras. 3.8 and 11.4).

Class, flag state and port state control (PSC) increasingly use MSC.581 as the benchmark in audits and inspections. If the crew can measure O₂, LEL, CO and H₂S but has no means of measuring CO₂, the ship risks a deficiency and, in the worst case, detention.

The right equipment: Riken Keiki gas detectors

As the official maritime partner of Riken Keiki in Germany, Woell Marine supplies, calibrates and services gas detectors for container vessels, bulk carriers, tankers and every other vessel type.

  • **GX-3R Pro** – personal multi-gas monitor for up to 5 gases at once, with an infrared CO₂ sensor. Fitted with the CO₂ sensor, it covers all gas groups listed in para. 8.2.
  • **RP-3R** – clip-on sample-draw pump for the GX-3R Pro. It lets you test a space via hose before anyone enters: 0.5 l/min sampling flow, audible and visual low-flow alarm, clips on in seconds without tools.
  • **GX-9000** – multi-gas detector with a built-in sampling pump for up to 6 gases and sampling up to 45 m. Its infrared sensor needs no oxygen to measure, which makes it suitable for inert atmospheres. IP66/68, ATEX/IECEx, MED approved.

See all devices on our gas detectors page.

Checklist: Is your ship ready for MSC.581?

  • Can your detectors measure CO₂, even in an oxygen-depleted atmosphere?
  • Does everyone entering an enclosed space carry their own calibrated gas detector for O₂, CO₂, LEL and CO?
  • Can you test the atmosphere from outside the space, using a pump and hose?
  • Have the Enclosed Space Register, permit-to-work and emergency response plan been updated in your SMS?
  • Are calibration and bump tests documented?

Frequently asked questions about MSC.581(110)

Is MSC.581(110) mandatory?

Formally, MSC.581(110) is a set of recommendations. However, it builds on mandatory rules – SOLAS XI-1/7 (atmosphere testing instruments), SOLAS III/19.3.6 (enclosed space entry and rescue drills) and the ISM Code – and serves as the benchmark in audits and inspections. Shipowners and operators should therefore update their safety management system.

When was MSC.581(110) adopted?

The IMO Maritime Safety Committee adopted MSC.581(110) on 27 June 2025. The previous resolution, A.1050(27), was revoked by the IMO Assembly in December 2025.

What CO₂ limit applies before entering an enclosed space?

Before entry, steady readings should show less than 0.5% CO₂ by volume (5,000 ppm), together with 20.9% oxygen (MSC.581(110), para. 7.4). National requirements may differ.

Is a 4-gas detector enough for MSC.581?

No, not if it does not measure CO₂. Standard 4-gas detectors measure O₂, LEL, CO and H₂S. MSC.581 calls for personal gas detectors that also monitor CO₂ (para. 8.2), and CO₂ detectors should work correctly even in an oxygen-depleted atmosphere (para. 7.1).

Not sure which setup fits your fleet?

Talk to Team Woell Marine in Hamburg. Together, we’ll find the right solution for your ships, from choosing the equipment to calibration.

+49 40 53 79 89 22 (24/7) · info@woellmarine.com · Contact form

Source

IMO Resolution MSC.581(110), “Revised Recommendations for Entering Enclosed Spaces Aboard Ships”, adopted on 27 June 2025 (MSC 110/21/Add.3, Annex 28). List of resolutions: IMO Index of Resolutions.